Controls module · Niagara module

In development · early access for design partners

Install it on any JACE. The station links itself to the record.

We are building a Niagara module for any Niagara JACE that links the station to EquipTalkIQ: once your controls contractor installs it, the station shows up with its equipment, points and alarms, on the same record as each unit’s manuals, warranty, service history and startup data. The owner’s IT picks how it connects, and it is read-only by default.

THE NIAGARA MODULE

A software add-on for the JACE. No new box in the panel.

The module is designed to install on a Niagara 4 JACE, whichever brand is on the label, the way other Niagara modules do. No custom integration per job and no hardware to stock.

  • The station appears in EquipTalkIQ with its equipment, points and alarms.
  • Points land on the unit record beside the manuals, warranty, service history and startup report, so the assistant reasons over all of it.
  • Once installed, the station links to EquipTalkIQ on its own: no custom integration per job, by us or by you.
  • Sold with controls contractors, not against them. They install the module; EquipTalkIQ does not sell controllers or do controls installs.
Preview · illustration
Niagara 4 JACEThe controller your controls contractor already installed+ EquipTalkIQ module
Unit record · RTU-3
  • Equipmentfrom station
  • Live pointsfrom station
  • Alarmsfrom station
  • Manuals and IOMon record
  • Warrantyon record
  • Service historyon record
  • Startup reporton record
How the Niagara module is meant to work. Names and layout are illustrative; the module is in development.

THE BMS STAYS ON THE BUILDING NETWORK

Three ways to connect. The owner’s IT chooses.

More owners keep the BMS off the internet, and they should be able to. Each option below keeps the building network closed to inbound traffic.

Preview · illustration

01Outbound-only

The module sends data out through the firewall; nothing connects in.BUILDING NETWORKJACE+ moduleFIREWALLout onlynothing inEquipTalkIQ
The module, or a gateway, sends encrypted data out. Nothing connects in, no firewall ports are opened, and no command goes back to the equipment.
Preview · illustration

02Separate cellular gateway

A separate gateway reads the controls and sends data over its own LTE connection, never over the owner's IT network.MECHANICAL ROOMBMSLTEgatewayOWNER IT NETWORK · NOT USEDown LTEEquipTalkIQ
A gateway with its own LTE connection reads the controls and sends the data out. It never touches the owner’s building IT network.
Preview · illustration

03Offline

The Startup Assistant reads the unit on site and the tech's phone syncs to EquipTalkIQ later; the BMS never touches the internet.ON SITE · NO INTERNET NEEDEDUnitboxsyncs whensignal returnsEquipTalkIQ
The Startup Assistant reads the equipment on site and syncs through the tech’s phone when it has signal. The BMS never touches the internet.

READ-ONLY BY DEFAULT

It watches. It never operates.

The same rule the app follows today: AI drafts and people decide, and nothing in EquipTalkIQ commands equipment.

No commands to equipment

The module reads points, equipment and alarms. It does not write a setpoint, override a point or command a controller.

Nothing connects in

Data leaves the building encrypted and outbound only. No inbound firewall ports, no remote session into the BMS.

Listens before it talks

On a live BMS network the Startup Assistant listens first, never takes an address already in use and polls lightly.

Writes stay behind a person

If writes or overrides are ever added, they will sit behind explicit confirmation and permissions. The first version has none.

WHERE IT STANDS

What you can use now, and what is being built.

We would rather show you the line than blur it. No ship date is promised on this page; design partners see each piece first.

In the app today

  • Controls views: points checked against expected ranges, beside each unit’s record
  • Findings with evidence that close themselves when the condition clears
  • AI site briefs written only from those findings
  • Demo readings are simulated; no live controller feeds run in the demo

In development

  • The Niagara module for the JACE
  • Outbound-only and separate cellular gateway connections
  • Offline readings through the Startup Assistant
  • Live points, equipment and alarms on the unit record

Not planned

  • Our own controller
  • Controls installation or commissioning work
  • Writing setpoints from the AI
Early access for design partners

Run it on a real building with us.

Early access is for design partners: mechanical contractors with controls in house, or a controls partner they work with, who will try the module on real buildings and tell us what is wrong with it.

THE RECORD OUTLASTS THE PROJECT

Win the job with cited answers.
Then keep the building talking.

Explore EquipTalkIQ with sample project data: takeoff, specs, planning, turnover, service, dispatch and controls.
Bring your questions. Follow the sources.